All this will be tied into your ground of your plug that has to be a twist lock and with a extreme duty cover 5 with a switchdisconnect. Conclusion how to bond an above ground pool.

Inground Pool Wiring Diagram H1 Wiring Diagram
Above ground pool electrical wiring diagram. Convenience receptacle outlet shall separate from the pool pump receptacle wiring. If a pump motor receptacle is located between. Watch this video to c how i install my electrical work from above ground pool. On in ground pools there must be at least one gfci protected convenience outlet located between 6 feet and 20 feet from the edge of the pool. Water and electricity are a dangerous combination installing a pool bonding wire helps mitigate the danger. Cord length for a pump motor is 3 except for storable pools.
10 horizontal from the pool wall. Plug in the pool pump and cover it with a weatherproof cover. Connect an 8 gauge wire to the metal posts of the pool the pump and the metal plate on the skimmer and then wire that to the pump to bond the entire pool. All electrical equipment used with storable pools are required to be gfci protected. Even if you have a temporary pool like an intex pool please take the time to put in a proper dedicated gfi plugoutlet and bond the pool and equipment. Electrical wiring requirements for swimming pools permanently installed swimming pools are those that are constructed in the ground or partially in the ground and all others capable of holding water with a depth greater than 42 inches 1067 mm 1 pool pump receptacle outlet and wiring method a.
2017 national electrical code sps 316 swimming pool wiring nec article 680 6805 gfcis may be either circuit breakers or receptacle type. The motor is to be grounded the pool is to be grounded in four areas with a 8awg bare wire making a circle around the pool. If electric is required to supply a pool filter pump motor or a pool low voltage underwater light fixture listed and labeled for us with a storable pool that is 42 deep or less nec article 6804 then your pool equipment must be served by a gfci protected. Can be existing andor wired with any approved wiring method see diagram 2 2a b. With the main service off to the house wire in gfci circuit breakers to the electrical panel. Also the water is to be bonded.
Convenience receptacle outlet must be gfci ground fault protected. Yes this is required by the national electrical code. If the pool is an above ground and is considered storable then the following codes apply. 6809 overhead wire clearance is min. Also is to be inspected by a wire inspector. No further than 20 feet from the outside of the pool wall.
All 125 volt outlets or receptacles within 2o feet of the inside walls of a pool require gfci protection. The only electrical requirements to a storable above ground pool are as follows. Gfci protection most devices and equipment serving pools or spas and the surrounding areas must be protected by ground fault circuit interrupter gfci devices.