It is used as a grounding transformer creating a missing neutral connection from an ungrounded 3 phase system to permit the grounding of that neutral to an earth reference point. Advantages of zig zag transformer.

Three Phase Custom Zigzag Transformer Matlab Amp Simulink
Zig zag transformer connection diagram. It is used to create a ground for the floating system and also to filter 3rd harmonics in 3 phase ac power supply system. The zigzag connection provides the same advantages as the y connection. Grounding transformers are used for obtaining a grounded neutral on three phase three wire systems providing a return path for zero sequence current generated by the loads in the system or by the fault currents. The windings a1a2 a1a2 and a3a4 are wound on the same limb of the core hence they are all colored red. The zigzag transformer contains six coils on three cores. Zig zag transformer for grounding system rev1 page 2 the zero sequence impedance of the zig zag transformer can contribute to limit the single line to ground slg fault current.
A zigzag transformer is a special purpose transformer with a zigzag or interconnected star winding connection such that each output is the vector sum of two 2 phases offset by 120. The first coil on each core is connected inside out to the second coil on the. What is zig zag connection. Less costly for grounding purpose it is typically the least costly than y d and scott transformer. The grounding transformer is commonly referred to by this connection type the zigzag transformer. This type of connection of transformer is not suitable for transforming power.
Third harmonic suppression the zigzag connection in power systems to trap triple harmonic 3rd 9th 15th etc currents. Zigzag transformer is a special purpose transformer. Less costly for grounding purpose. The zig zag connection is the most widely used grounding transformer. In zig zag transformer connection there are three windings on each of the three limbs of the core one for primary and two for secondary. To perform harmonic.
The zigzag transformer is a special type of 3 phase transformer. Zigzag transformer has six coils in which three. The zigzag connection provides the same advantages as the y connection. If there is a zero sequence impedance of transformer the power and leakage impedance rating of the transformer may be calculated. Zig zag connection is the combination star and delta connection and it has the both advantage of a star and delta. It is used in power system zigzag connection has some of the features of the stary and delta connections.
Zigzag transformer zigzag transformer is also known as the interconnected star connection. The zigzag connection in power systems to trap triple harmonic 3rd 9th 15th etc currents. Both the windings of secondary are of equal turns. The most common connection used in grounding transformers is the zig zag connection. Advantages of zig zag transformer. It is typically the least costly than y d and scott transformer.
Zig zag transformer winding outer layout. Figure 1 grounding transformer connections zig zag and grounded wye delta figure 2 shows how a grounding bank supplies current to a ground fault.