The electric meter exists so that the power company can monitor current usage and bill you accordingly. 4s wiring diagram 1 ph 3 wire 1 pt 2 ct glems would like to thank and acknowledge the use of the following meter connection diagrams from dr.

Meter Installation Process Duquesne Light Company
Meter socket wiring diagram. Meter sockets single position and multi position multi gang self contained meter sockets house the utilities electrical watthour meters in residential and commercial buildings. The form 2s meter wiring diagram. Form 4s meter wiring diagram. Engineering data meter socket circuit diagrams 174 data subject to change without notice. Metering data 127 meter mounting equipment location of socket jaws 4 terminal form 1s 2s 5 terminal form 3s 7 terminal form 14s 15s 16s 17s 24s 8 terminal form 5s 35s 45s 15 terminal form 11s 39s 76s 13 terminal form 6s. The electric meter is usually a clear glass encased metering device resembling an over sized mason jar.
Meter a device for measuring the electric power and energy supplied to a customer. Internal potential wiring of 13 14 15 jaw sockets front view. The only difference is that it is larger. Because utility configuration requirements vary widely eaton offers the widest range of utility approved sockets in the industry. This page contains circuit type and wiring diagrams for all the form s of meters sockets and pans. Regardless the meter socket for the form 2s meter is wired the same way.
Meter sockets a meter socket is the base portion of a socket type meter. With and without cts and pts for wye delta and network circuits. For the form 4s meter wiring diagram lets start at the bottom. Inside the glass houses the measuring devices that include dials and wheels on the older model meters. Ok now that we know where the form 2s meter is installed lets take a look at the form 2s meter wiring diagram. This means that the meter is in series with.
Notice that we are going to be metering a single phase three wire service. Make note that this is the same type of service that you find on most homes. Notice that the form 2s meter is what is known as a self contained meter form. Meter enclosure a wood or metal cabinet or metal socket installed indoors or outdoors in which the companys metering equipment is located. All dimensions are in inches. With safety test by pass blocks current transformer installations 3 wire 1 2 3ø or network 3ø 4 wire y or 2 element meter meter disconnect line n load line line n or 2 load line n or 2 load bondable neutral bondable neutral load bypass for use.
One of the most requested items of information that we receive is for wiring diagrams for the meters we sell. We have two phase wires and a neutral. Be aware that these are general diagrams using standard test switches which may not match some utility standards in their configuration and are for reference only.