Mixing valves are more commonly used in the hvac field. The b port restricts fl ow by 30 of a port value.

Learn More About Hvac Three Way Valves Industrial Controls
3 way mixing valve piping diagram. 3 way valves must be piped correctly. The belimo b2 series 2 way ball valves and b3 series 3 way ball valves are used for two position floating or proportional control of hvac hot or chilled water. Mixing valves make good modulating valves although they can be used like two position valves taking the full flow from one or the other inlet to the common outlet. Y mixing valve piping diagra three way diverting valve piping diagram. 6 installation in the supply or return is dependent on the selected hydraulic circuit. Mixing valves are designed to blend hot water with cold water to ensure a constant safe outlet temperature.
Mixing is the preferred piping arrangement. L it is commonly accepted that a thermostatic mixing valve provides energy savings of 30 compared to a simple. They can be mixing or diverting. The a port must be piped to the coil to maintain proper control. A diverting valve receives input flow at one port and diverts the flow to one of two output ports. Note that the distribution circulator is located between the mixing valve and the manifold station.
Use a mixing valve. Hot water enters port a and mixes with cool return water entering through port b. Diverting valves are usually used as two position. The proper piping of a three way thermostat valve is shown in figure 1. The type of valve used is dependent upon the piping of the application. They vary in size from 2 to 6 pipe diameter and have a cv range of 68 340 three way mixing 68 248 three way diverting.
Valves a mixing valve receives input flow at two ports and discharges the mixed flow at the third port. The resulting mix flows out through port ab and heads for the radiant floor manifolds. Call leonard valve today at 800 222 1208or watch our recirculation video under videos. 3 way valve flow rate for water applications gallons per minute gpm. L it significantly increases the output capacity of the accumulator. The belimo characterized control valve is a control valve not a manual valve adapted for actuation.
This valve design has three ports on it with the plug in this particular case a cage guided plug controlling the degree to which two of the ports connect with the third port. Not sure which piping diagram to choose. Another style of globe valve body is the three way body sometimes called a mixing or a diverting valve. They are utilized in residential commercial and institutional applications where controlling water temperature is critical to avoid scalding thermal shock and legionella growth. Important v5013 valves should not be piped backwards. Mixing or diverting valve.
The flow is totally diverted either one way or the other. Generally speaking diverting valves do not make good modulating. L the interchangeable mixing valve mechanism eurothermalso contributes to savings while making it possible to renovate a mixing valve at a limited cost.