Simplex 4002 wiring diagram free pdf download at fire alarm resources your home for free fire alarm manuals catalogs software and more. Dfu7003001 rev 2 5 cfp 248 zone fire alarm repeater panel the network wiring should be installed to meet bs 5839.

Section 13850 28 31 00 Fire Detection And Alarm System
Fire alarm repeater panel wiring diagram. Connecting a repeater panel. In either case the shield of the cable must be securely bonded to the panel case at both ends. From control panel rs485 and to next repeater rs485 and shield bonded to case of panel shield bonded to case of panel 24v dc wiring can be standard fire alarm cable such as fp200 or shielded data cable. Re rp series are a range of repeater panels compatible with fire alarm panel. This is in addition to the standard requirement of a printed zone chart beside each panel but could be incorporated in the form of a mimic diagram with zonal indication. Communication between the xfp main panel and repeater requires a cfp761 network driver card fitted as standard in all xfp510 16s available as an optional extra on main xfp 16 zone panels.
Actually two type of repeater panel available in market. Hence repeater panels are no exception. All wiring for the fire system should be in fire resistant cabling including the mains supply. A maximum of eight xfp repeaters can be connected to one non networked xfp main panel. Risk of damage to eolm 3 if correct wiring polarity is not observed eaton coventional fire panel only supports the eolm 1 do not attempt to use any other type of eolm module or use any resistor value. Cable types and limitations.
What exactly is a repeater panel. First is passive repeater panel second is active panel. It repeats function like fire fault supervisory etc that occur on the main panel. Fire alarm system is the combination of different components such as smoke detector heat detector carbon monoxide detector multi sensor detector call points sounders bells relay module repeater annunciator fire control panel and other related and optional security devices designed for fire alarm control system. Repeater panel is use to display main fire panel information as well as user can control some of parameter from it. Cfp repeater panel installation maintenance manual approved document no.
Other national standards of installation should be used where pertinent. The repeater panel is connected to the facp via the rs485 using cat5e 2c15sqmm shielded twisted pair communication cable. Can be used to repeat the functions of a master cfp standard or alarmsense 2 8 zone fire panel at remote parts of site eg. Re rpseries is a conventional fire alarm repeater panel. Includes its own mains power supply that requires its own standby battery supply. Hi all of you.
Repeater network wired in 15 mm2 two core screened fire resistant. Fire alarm routing equipment fre. Provides the user with access to all al1 and al2 functions. 1988 and bs 7671 wiring regulations. Each repeater must be allocated a. Up to 8 repeaters per cfp master.
All potential fire service entrances.