To wire an outlet to be hot at all times or both receptacles to be switched requires a 3 wire cable. There was no dedicated ground slot on the receptacle outlet and dryer cords had no ground wire or ground prong.

How To Wire Twist Lock Plugs
4 wire outlet wiring diagram. If you were installing a four wire 220 outlet chances are its for a stoveoven. Clamp a wire stripper around the outlet end of the 104 cable so its 1 foot 30 cm from the end. The outlet addition methods we show here are based on the most common wiring 14 gauge wire on a 15 amp circuit and an 18 cu in. Pull the wire stripper toward the end of the cable to cut through the outer coating and expose the wires inside. Wiring a switch to an outlet in one box. In these older appliance installations where 3 wire cords were legally installed the wiring consisted of two hot wires and a neutral wire.
Steps to take when wiring the electrical outletreceptacle. The hot source connects to one terminal on the switch and the other terminal connects to the hot on the receptacle with a short wire. Remove 1 ft 30 cm of the outer coating of the 104 cable. This wiring is commonly used in a 20 amp kitchen circuit where two appliance feeds are needed such as for a refrigerator and a microwave in the same location. These wires are a lot harder to handle and thread through the walls and ceilings and generally cost a lot more than your normal 12 and 14 wires. This system worked pretty well and is still in use in many homes today but there is more potential for electrical.
So either 6 or 8 wire. Two hot wires and the third contained both ground and a neutral wire. Box typical inside dimensions are about 2 in. Before 1996 electric dryers were supplied by a dedicated circuit that had three conductors. In this diagram a switch and receptacle outlet are installed in the same box and the switch controls the power to the outlet. The neutral line is a return line for the voltage and should not be done through the green ground wire even though a neutral and ground are really the same so new codes require a dedicated neutral line as well as a dedicated ground line.
The neutral wire from the circuit is shared by both sets. The 4th wire in that cord and plug configuration is an equipment grounding conductor. The difference between this diagram and the 4 prong outlet below is the addition of a neutral wire. 4 wire outlet the wire. To wire an outlet so that only the top or bottom receptacle is switched and the other receptacle remains hot all the time requires a 4 wire cable. Wiring diagram for dual outlets.
This equipment grounding conductor is the missing wire in the older 3 wire configurations. You need to know up front which scenario you prefer if your wiring a new circuit. Now this could be either 40 or 50 amp. Here 3 wire cable is run from a double pole circuit breaker providing an independent 120 volts to two sets of multiple outlets. How to wire an electrical outlet wiring diagram wiring an electrical outlet receptacle is quite an easy jobif you are fixing more than one outlet the wiring can be done in parallel or in series.