The op is installing a 400 amp service using 2 200 amp panels. What all do you plan on having at your place a commercial wood shop butcher shop.

Electrician By Jules Bartow Goldvein Power Amp Automation
400 amp residential service diagram. To be parallel they must begin and terminate together. Most houses a 200 amp service is plenty even for most home businesss. Refer to the example attached. What i dont get is why there is only one screw to split 1 line side and 2 load side neutrals. This type of meter base uses a transformer in the panel to step down the power before it flows through the meter. The use of a transocket cts in switchgear see subsections 5 6 and 5 7 or overhead ct metering see subsection 5 8.
Metering for 400 amp services or less. Some areas do require the use of ct current transformer metering for a 400 amp service. 400 amp service drawings or diagrams well this is the first time ive had to use one of their 400 amp meter bases. By the way i dont believe 2 200 amp panels are considered a parallel install. Example diagrams are attached for your information in preparing a single line diagram. Both panels will be located approximately 20 feet from the meter location the meter will be located on the exterior of the dwelling and the panels will be located on the interior.
Installed everything from 100 amp to 400 amp panels and the only place that ever needed 400 amp service was commercial businesss. If any of these diagrams do not meet your needs. Like wanda said pumps dont need a lot unless you get really big. Existing house has 200 amp underground service with 40 aluminum lateral and seu from meter to 200 amp panel. Voltage requirements size of service riser diagram etc is required. With ct metering there are several options.
I have one overhead 400 amp residential single phase service figured to be fed from overhead with paralleled 40 cu in 25 pvc to the service head. Voltage for residential services is 120240 volts except for special situations. See my so called diagram below. I am to use the split lugs and proceed with the installation. 31015b6 is not allowed that is a 400 amp service. That being said years ago 100 amp sevice.
It comes equipt with screws where the split lugs are to connect. Additionally for multi tenant buildings the building addresses and unit numbers are needed as early as possible. Ct metering is required for 400 amp and larger single phase 400 amp and larger 120208 three phase and 400 amp and larger 277480 three phase. Current rating typical use comment less than 200 amps. Your local grovers sales team can advise you if this is the case in your area. Residential service is defined as service to a single family residence.
Single line feeder diagram nec 215 5. Buildings structures fences pools spas etc and the location or area where the service and panelboards are to be installed. Services up to 400 amps are single phase. An outbuilding is being upfitted with an additional 200 amp panel and a 40 underground line from the house meter location to the outbuilding to a new 200 amp panel. Service to a multi family residence such as an apartment or condominium is a business ser vice.